| Model |
Maximum Recommended Remote Sense Line Drop Compensation per Line 9 |
Up-prog. Response Time, 0~Vmax 10 |
Efficiency
(100/200 VAC input) 11 |
|
| XTR 6-110 |
1 V |
60 ms
|
75/77%
|
| XTR 8-100 |
1 V |
60 ms
|
77/80%
|
| XTR 12-70 |
1 V |
60 ms |
79.5/82.5%
|
| XTR 20-42 |
1.5 V |
60 ms |
82/85%
|
| XTR 33-25 |
2 V |
60 ms
|
83/86%
|
| XTR 40-21 |
2 V |
60 ms
|
83/87%
|
| XTR 60-14 |
3 V |
60 ms
|
83/87%
|
| XTR 80-10.5 |
5 V |
100 ms
|
83/87%
|
| XTR 100-8.5 |
5 V |
100 ms
|
83/87%
|
| XTR 150-5.6 |
5 V |
100 ms
|
83/87%
|
| XTR 300-2.8 |
5 V |
150 ms
|
83/87%
|
| XTR 600-1.4 |
5 V |
250 ms |
83/87% |
|
 |
|
 |
| Model |
Down-prog. Response Time: Full Load |
Down-prog. Response Time: No Load |
Over-Voltage Trip Point |
|
| XTR 6-110 |
60 ms
|
300 ms
|
0.5–7.5 V
|
| XTR 8-100 |
60 ms
|
400 ms
|
0.5–10 V
|
| XTR 12-70 |
60 ms
|
500 ms
|
1–15 V
|
| XTR 20-42 |
60 ms
|
600 ms
|
1–24 V
|
| XTR 33-25 |
60 ms
|
700 ms
|
2–39 V
|
| XTR 40-21 |
60 ms
|
800 ms
|
2–44 V
|
| XTR 60-14 |
60 ms
|
900 ms
|
3–66 V
|
| XTR 80-10.5 |
100 ms
|
1000 ms
|
3–95 V
|
| XTR 100-8.5 |
100 ms
|
1200 ms
|
3–125 V
|
| XTR 150-5.6 |
100 ms
|
1800 ms
|
3–180 V
|
| XTR 300-2.8 |
150 ms
|
2200 ms
|
5–330 V
|
| XTR 600-1.4 |
250 ms |
3500 ms |
5–660 V |
|
 |
|
 |
| Environmental Specifications (Indoor use) |
|
Operating Temperature Range
|
32°F to 122°F, 100% load (0°C to 50°C)
|
Storage Temperature Range
|
-4°F to 158°F (–20° C to 70°C)
|
Operating Humidity Range
|
30–90% RH (no condensation)
|
Storage Humidity Range
|
10–95% RH (no condensation)
|
Operating Altitude
|
Up to 6,500 feet (2,000 m)
|
Installation Category
|
II (IEC 1010-1)
|
| Pollution Degree |
2 (IEC 1010-1) |
|
 |
|
 |
|
Safety
|
CSA 22.2 No. 61010-1 and UL61010-1. Marked with cCSAus, CE EN61010-1
|
EMC
|
Complies with EN61326-1
Complies with EN55022, Class B, FCC Part 15B for conducted emissions
Complies with EN55022, Class A, FCC Part 15A for radiated emissions
Complies with EN61000-4 series of standards for immunity
|
|
 |
|
 |
|
 |